• Frigo Panel
    Frigo Panel

    The solution for Industrial refrigeration is arkhon Frigo panels. Our specially designed geometry system joint and the diversity in thicknesses from 20mm up to 200mm offer the best performance in each use. Arkhon Frigo panels provide reliable insulation conditions from +60oC-50oC.

  • Horizon Panel
    Horizon Panel

    Thermally insulating polyurethane panels, with hidden joints and ability to be mounted both vertically and horizontally. Smart hidden joints with double locks, ensure continuous watertight surfaces with unique thermal and sound insulation.

  • Sky Panel
    Sky Panel

    Arkhon's thermally insulating polyurethane panel, Sky, is the best solution for cost effective constructions with spectacular aesthetics.

  • Purlings
    Purlins

    High strengh zinc-coated steel Z & C purlins. The most important part for an efficient, lightweight and secure construction.

  • Roman Tiles
    Roman Tiles

    Supreme Arkhon technology, has evolved roman tiles to bring your building's eco friendliness to the next level, without sacrificing aesthetics.

How to use this section


Use the tabs on the right to navigate through various properties of this product. Right beneath those tabs you will find more information about our polyurethane panels. You can navigate there by clicking the underlined links. The active menu will always be highlighted in blue-ish color. If you have any difficulties using our website contact technical support

Lorem ipsum dolor sit amet, consectetur adipisicing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.

Roman Tile Polyurethane Panel


  • Premium design, advanced thermal insulation

    Arkhon Roman Tile image

    Arkhon Roman tile is the insulating polyurethane metal panel at the shape of the traditional Roman tile offering unique aesthetics and high thermal insulation (k = 0,022 / U = 0.258 kcal / m2 ho C).
    Is produced in long metal sheets and is available in matt shades or aged paints.

      The main advantages of Arkhon Roman Tile are:
    • Easy and safe installation (low weight in long dimensions)
    • Particular aesthetics
    • 100% water tightness
    • Direct application

    The ARKHON ROMAN TILE can be placed on existing roof structures that suffer from roof leaks and insulation problems, providing energy and aesthetic upgrade.

    Strict control of raw materials, fully automated industrial production, constant research and expertise of the staff, guarantees customer satisfaction.

    The installation guide showing all the ways to connect the panels in order to achieve the best results in thermal insulation, water / air tightness and fire resistance .

    The panels are produced mostly from galvanized pre-painted steel sheets, however there is the possibility of producing them with aluminum sheets or stainless steel.

    Regardless of the type of the project you design, there will always be available our engineering team to assist you finding the best solution with panels in your application.

  • Product Applications

    The arkhon roman tile Panel, available in a single step (pressing 35centimeters), is forming an outstanding architectural effect.

    The Panel arkhon roman tile can be used in a multitude of applications such as e.g. in metal buildings covers, sports facilities, partitions, food processing areas, bungalows, lightweight construction and generally in all applications requiring roof cladding.

    Also Panel arkhon roman tile can be used as an addition to existing housing construction (metal or conventional), offering excellent optical effect and mainly energy upgrade of the building.

  • Weight and Geometry Tables

    Thickness of the polyurethane panel (mm) 60
    Overall panel height (mm) 95
    Weight kg / m2 (0.50mm) steel 11.19

    Maximum dimensional tolerances

    Length (ISO 2796) L ≤ 3m ±2mm
    L > 3m ±2mm
    Width (ISO 2796) ±2mm
    Thickness (ISO 2796) D ≤ 100mm ±2%
    D ≥ 100mm ±2%

    Polyurethane Features

    Density (ISO 845) 40-42 Kg/m33
    Percentage of closed cells 98%

    Available lengths

    Available lengths up to 15 meters (means of transport limitation) for larger sizes please contact us.

    Indicative lengths in accordance with step (length tile) 35cm:

    Number of Tiles Panel length
    1 700mm
    2 1050mm
    3 1400mm
    4 1750mm
    5 2100mm
    6 2450mm
    7 2800mm
    8 3150mm
    9 3500mm
    10 3850mm
    11 4200mm
    12 4550mm
    13 4900mm
    14 5250mm
    15 5600mm
    16 5950mm
    17 6300mm
    18 6650mm
    19 7000mm
    20 7350mm
    21 7700mm
    22 8050mm
    23 8400mm
    24 8750mm
  • The following load tables are created in accordance with EN 14509. Values are indicative based on plate thickness 0.5 / 0.5mm and minimum thickness purlins 1.5mm and width 40mm, a maximum permissible deflection L / 200.

    Τα παρακάτω ανοίγματα έχουν υπολογιστεί:

    Simple span
    Panel thikness
    Supports spacing (m) Multiple span
    Panel thikness
    60 60
    Max load capacity kg/m2 steel Max load capacity kg/m2 steel
    0.5/0.5
    344 2 558
    280 2.5 441
    220 3 300
    160 3.5 220
    115 4 170
    82 4.5 120
    62 5 90
    0.6/0.6
    366 2 571
    300 2.5 465
    235 3 325
    171 3.5 235
    123 4 182
    88 4.5 128
    66 5 96
  • Flashings for Arkhon Roman Tile.

    For the complete and correct installation of Arkhon Roman Tile, roof panels, required a series of flashings in order to perfectly place the insulation and get the best aesthetic appeal of each construction.

    Since most of the buildings have their own unique requirements (always based on the architectural and structural design), required flashings vary from case to case. Our technical department is always available to serve and meet your every special need.

    More Accessories
  • How to connect Arkhon Roman Tile

    The potential of the right joint. All the know-how to insulate without discontinuities, contained in specially developed and designed panel joints.

    1. Anti-capillary groove
    2. Silicon is not required
    3. Double micro gutter for water tightness
    4. Guaranteed thermal transmittance U value
    5. No thermal bridge or big gaps
    6. Insulation continuance
    7. Slope from 5 degrees
    8. 8 Special color coatings for zero maintenance

    Installation Guide

  • Panel Surfaces

    Technical characteristics of steel (ΕΝ 10169-1/03 - ΕΝ 10142/00 - ΕΝ 10147/00 & ΕΝ10142/00)

    Quality Steel DX51D or S320
    Thickness 0.30mm – 1.00mm
    Coating (Z) Zing or (AZ) Galvalume or (ZM) Magnelis
    Tensile strength EN 10142/00

    Coating Characteristics

    1. 1. Organic Polyester Paint EN 1069-2/99. Paint thickness up to 25/5 mic.
    2. 2. PVDF Organic Paint. Paint thickness 25-50mic.
    3. 3. Galvanized Steel with PVC coating. Lamination thickness 120 mic*.
      *Suitable for sanitary clean rooms. PVC is available in RAL9002 color.

    Additional Surfaces

    Upon request we can meet special demands for extreme or unusual environmnets, such as farm houses, sea salt processing factories, acidic environments etc

    We can offer:

    • Stainless steel
    • Aluminum
    • Copper
    • Alupaper
    • Craft Paper
    • Embossed Alufoil
    • Agricultural Fiberglass

    For special surfaces, please contact us directly.

  • Support & Waterproofing equipment

    Properly mounting our panels require a series of connecting materials that Akrhon can provide depending on your project (self-piercing bolts, washers etc).

    We also provide special materials for waterproofing constructions (like butylate string, foam gaskets etc) that are subject to very humid environments.

    For bolts with longer piercing ability, please contact us.

    Panel thickness (mm) Bolt Type Penetration ability
    30 6.3 x 50mm 8mm
    40 6.3 x 60mm 8mm
    50 6.3 x 70mm 8mm
    60 6.3 x 80mm 8mm
    80 6.3 x 100mm 8mm
    100 6.3 x 120mm 8mm
  • Arkhon Panels Energy Efficiency Data

    Our panels are manufactured according to the European Standard ΕΝ 14509 (CEN/TC128/SC110).

    Acoustic efficiency

    Arkhon panel acoustic efficiency has been calculated with the use of specialized software. The results in the following chart are based in arkhon sky 80mm.

    Sound Reduction Index (SRI)

    Frequency Hz SRI dB
    125 17.2
    250 20.0
    500 23.2
    1k 23.4
    2k 23.2
    4k 40.5

    Air Tightness

    According to EN 14509 and EN 1214, the air permeability must not exceed 10m3/Ω/m2. As in all previous tests, so in the air tightness test, Arkhon panels surpass these limits.

    Water Sealing

    The basic compliance standard for sealing control in polyurethane panels is EN 12865. The model requires attaining a pressure seal 600 a under normal conditions. Laboratory tests showed that arkhon panel is watertight up to the pressure of 1070 Pa, far beyond the requirement of the system.

    Fire behavior

    PUR : Β2 – Β3

    PIR : 100mm RE130

    Environmental Care

    Our company uses environmentaly friendly policies with reusable materials and we produce polyurethane without harmful materials HCFC & CFC.

    Images showing how Environmentally friendly manufacturing of Arkhon Panels is
    Images showing how Environmentally friendly manufacturing of Arkhon Panels is
    Images showing how Environmentally friendly manufacturing of Arkhon Panels is
  • Packing – Storage - Handling

    All arkhon panels are packed in the factory and protected to ensure they arrive on site in first class condition. The number if pieces in each pack vary from product to product because of their shapes.

    In all cases however the panels are packed horizontally, with panels lying one on top of another, with additional anti damage protection to all sides and ends. The entire pack is wrapped in plastic film to keep the panels clean.
    The number of panels in each pack varies depending on panel thickness, and customer requirements. Normally the maximum height of each pack is approximately 1100 - 1200mm. Each pack is labeled with the customers name and contents.

    Panels are normally delivered to the site by road transport, the number of packs depending on panel and pack size. The packs are separated with polystyrene blocks, which create gaps between the packs to allow lifting straps or forklift tines to be inserted. It is the customer’s responsibility to arrange lifting equipment and labor to unload the packs.
    This usually requires using a crane, with or without a lifting beam, or a forklift, depending on panel length and weight. When hoisting packs or panels into position protect the edges if necessary to avoid damage. Use flat slings and not chains for hoisting. Packs of panels up to 6 meters long can be lifted either with a forklift, or by crane with lifting straps, as shown below.

    Σχεδιάγραμα δεματοποίησης και μεταφοράς των Arkhon Panel

    Note: Care must be taken to ensure the forklift tines do not damage the bottom panel, and similarly when using straps, protect the edge of the panels to prevent local damage. For panels > 9.0m use of a slip-on fork spreader is recommended to distribute load across its full length to avoid panel damage and "sagging".

    Receipt of Goods

    All materials arriving on site should be checked promptly against relevant advice or delivery notes to ascertain correct quantities, specifications and lack of damage. Any shortages or damage should be reported within 24 hours of receipt of goods on site.

    Site Storage

    It is often necessary to store packs of panels on site for a period before they are fixed. To ensure that the panels remain in prime condition until they are installed the following precautions should be taken.

    • Store packs off the ground and on a slope, so that should rainwater penetrate the wrapping water will drain away. Support the packs evenly with timber bearers spaced at 1.5 meters. Bearers should always be placed one directly above another
    • If packs cannot be kept in a building they should be covered with a weatherproof sheet ensuring that the sheet drains water away effectively and does not allow ponding on top of the pack. It should also allow air circulation through the stacks of panels.
    • Protective film applied during production process should be removed while installing the panel, however no later than two months from date of purchase. After short-term exposure to weather conditions the film may start to crack, making it difficult to remove.
    • Store packs in a secure area, where they will not be damaged or stolen.
    • Inspect the storage site and the packs regularly to ensure the panels remain in good condition
  • Panel Terms of Usage

    SUBJECTAND PARTIESTOTHE CONTRACT

    The General Sales Terms hereby rule all the sales of products (from now on the " Products" manufactured or sol d by t he manufacturing company or the supplier (from now " The Seller") to the customer owner of the related invoices (from now on " The Customer") and take priority on every different clause or forecast (even though not specifically disputed by THE SELLER) which is inserted in modules, offerings or other documents. The Sellers reserves the right to change Its Products - at any time and without notification - or to improve them as it sees fit or necessary.

    ORDER - APPROVAL

    The Customer 's order, that must be written using the ordering forms prepared by THE SELLER, must be considered as a proposal and it is irrevocable from The Customer for 30 (Thirty) days after it has been sent to The Seller. The order becomes binding once the Customer receives the written order confirmation from the Seller, which has approval value and it is the only document binding the two parts and ruling the contractual relationship, concerning everything not stated in the "General Sales Terms" hereby. If the order confirmation includes the supply of different type of Products and/or multiple shipping, every type and/ or shipping is to be considered autonomous in respect to the other by virtue of contract.

    MATERIAL DELIVERY, SHIPPING AND TRANSPORT

    The delivery terms stated in the order confirmation are calculated in working days, they are not essential and they can be subject to changes; the Seller will notify the Customer those changes as soon as possible. Anyway a tolerance of 15 days is allowed. Moreover, partial deliveries are always allowed.

    The Seller will not be held responsible to the Customer for delays, losses, damages, costs or expenses caused by for instance, but not limited to - industrial actions (even if business strikes), lockouts, transport blocks or suspensions, chance, fires, import prohibition s, raw material delays or lack of supply, power source limitations, raw material scarcity or absence, adaptation to law regulation, government measures, right full or not, insurrections, war or similar, natural catastrophes, embargo, and any circumstances beyond reason able control. The Seller will not be held responsible for those events not even if, when they happened, the delivery were already late in respect to the contractual terms. If the causes of the delay last beyond 30 (thirty) days, the Seller will have the option to rescind the contract without this implying the Customer's right to be refunded for t he loss attributable directly o r not to t he delay. When t he agreed terms of delivery expire, within 15 (fifteen) calendar days from t he reception of t he Product -ready notification, the Customer will have to pick up the ordered Products, or, in case of recipient delivery, the Customer will have to request the shipping.

    Once this date is expired, the Products can be stocked outdoors, and this will relieve the Seller of any responsibility for the Product contingent flaws in consequence of the exposition to the weather; any warranty for the Customer will expire and he will be charge d extra movement and stocking cost of 1% of t he Product value per stocking w eek. The sellers has also the right to ship t he Products in a port assigned to the Customer, or to stock them at the expense of the Customer, or, finally, to sell the Products that we re not picked up promptly by the Customer to third parties charging the former for possible payments or greater damage. After 8 (eight) days f rom the issuing of the read y Product notification, the invoice will be issued anyway and the payment terms will transpire. Possible evident flaws or missing Products must be reported at the delivery taking not e on the customer receipt or the warranty will expire.

    PACKAGING AND PROTECTION

    The Products are provided without packaging. Possible packaging must be requested when issuing the order and they will be charged in the invoice. The choice of the packaging type - which has to be made by the Customer, according to the need of Product transport stocking and destination - and all the related responsibilities resulting from that choice are exclusively and totally the customer 's responsibility, with express exclusion of any Seller responsibility. The Customer is notified that using wrong or inadequate methods of shipping, transport, stocking, movement or assembly can cause condensation and oxidation phenomena and it can compromise severely – and sometimes permanently - the Product quality.

    To ensure the panel and the prepainted ribbed sheet aesthetical integrity, it is essential that those surfaces during manufacturing, movement, transport and assembly are protected with a polyethylene sticky film which must be removed by the Customer before assembling the Products, anyway, within 8 (eight) days from t he Product delivery. If the Customer does not remove the film within the terms mentioned above, this can cause extreme film stickiness removal issues, and sometimes-unexpected interactions with the organic layer below, compromising the Product quality and aesthetic. The Customer asking or accepting ribbed painted sheet or panel without that protection supply, accepts the responsibility and relieves the Seller for any kind of damage.

    If the above-mentioned expedient will not be adopted, the possible protest for affirmed sticky film anomalies and/or consequences directly and/or indirectly imputable to the already-mentioned film will not be accepted by the Seller.

    TOLERANCES

    The customer accepts the tolerances noted on the catalogue and/or on the Seller technical sheets (last edition).

    WARRANTIES

    The Seller guarantees to the Customer the Product compliance to the specifications found in the catalogues and/or in the Setter technical sheets (last version), and also the flawlessness of materials and Product manufacturing, within the tolerances and within the technical specification given by the Customer. The warranty stated above lasts 12 (twelve) months after the Product delivery date. Possible protests concerning evident flaws in the Product or shortage must be enrolled (through notified registered mail or early faxed telegram) by the Customer to the Seller within 3 (three) days from the Product delivery. Possible hidden flaws not revealed at the delivery must be reported by the Customer- in the same ways for the evident flaws - within and not after the expiring one year warranty date and, at penalty of forfeiture, within 8 (eight) days from the discovery or from the moment they should have been discovered using ordinary care. The protests must be detailed to allow the Seller a prompt and complete check. The Products subject to protest must be at Customer disposal exactly how they have been delivered, respecting the movimentation, handling and stocking legislation hereby and possible particular instruction provided by the Seller. It is understood that, in any case, the following cases cannot be considered Product flaws: Oil the presence of possible cunning imperfection with less than 1,5 mm protrusion in relation to the metal support plane.

    Oil the presence - when manufactured with overlapping to allow the element lengthwise overlapping - of expanded material residual on the metal surface after the automatic removal of the insulation (the removal from the naked metal must be completed on the working site during the building and it will be charged to the Customer) Condition alto the above provisions fulfillment, in case of prompt flaws complaint by the Customer and Acknowledgement of those flaws by the Seller, the latter will proceed according to the necessary steps and by its own undisputable choice to freely repair and/or substitute the Products Ex Works (EXW), or to refund the Customer a sum co responding to the difference between the ordered Product price and the product price degraded by the flaws (being understood that, In any case, the sum refunded by the Seller to the Customer according to hereby paragraph (ii) can never exceed the flawed product original price). The repaired or substituted product warranty according to the hereby paragraph will expire at the original intended date set by the original Customer purchase. Whereas complaints issued by the Customer concerning flawed Products should reveal themselves false, the Seller will charge the Customer all the costs sustained by the former for reviews, inspections, and possible surveys (also made by third parties).
    The warranty mentioned above is the warranty offered by the Seller to the Customer in relation with the Product sales, it will have validity and it will not be interrupted or extended in any case. No other type of warranty and/or refunding, whether convention al or legal can be requested by the Customer to the Seller. In particular every responsibility of the Seller for direct, in direct, accidental or consequential damages which the Customer may experience from the Product defectiveness and/ or non-conformity (as for delays in the delivery) is excluded. The right of refund of these damages, limited by law, is to be considered renounced by the Customer. The Customer’s right to terminate the contract based on possible Product flaws is excluded. In case of separate deliveries, possible protests, even if promptly made, related to some of the products delivered do not relieve the Seller from the obligation to recall the remaining Products ordered. In dispensation of what is stated above, no warranty is issued by the Seller for metal layer Products without organic covering, except for the warranty of Product correspondence to the regulation in force; the Seller is then relieved from any responsibility related to the possible (and likely] oxidation phenomena occurring on those Products .

    Likewise, no warranty is issued relating to used or secondhand Products, or to Products purchased with the “seen and liked “system, made of available material (whether it is first choice, second choice or junk material) by the Seller’s factory and sold at lowered prices. The warranty described in paragraph 6 automatically expires (and any Product warranty expires as well) in case of:(i) use and/or placement of Products declared flawed by the Customer after the notification expiring date or flaw onset, whichever happens first; (ii) use of Products not according to the related "performance" features; (iii) use, stocking, maintenance, movement or assembly of Products not according to the "movement. (iv) Installation with systems or accessories not according to the Seller technical sheets (last edition) or with accessories (for instance: fixing systems, tampons, ribs fixer, ridges, flashings, etc. which are not provided and/or explicitly approved by the Seller ;(v ) Product s on which intervention of any kind has been made by third parties other than the Seller.

Business Hours

Our support Hotline is
available 8 Hours a day

Monday-Friday: 9am to 5pm
Weekend: Closed

Contact us

Viemetal Group

  • Industrial Area

    BI.PE. Patras
  • Branches

    Italy, Bari
    United Kingdom, London
    North Greece, Thessaloniki
Arkhon Polyurethane Panels Offices